 Micrel, Inc.
2-BIT 8:1 MULTIPLEXER
SY10E163 SY100E163 SY10E163
SY100E163
FEATURES
s 850ps max. propagation delay s Extended 100E VEE range of -4.2V to -5.5V s Differential outputs s Internal 75K input pulldown resistors s Fully compatible with industry standard 10KH, 100K ECL levels s Fully compatible with Motorola MC10E/100E163 s Available in 28-pin PLCC package
DESCRIPTION
The SY10/100E163 offer two 8:1 multiplexers designed for use in new, high-performance ECL systems. The E163 has differential outputs and common select inputs. The select inputs (SEL0, SEL1, SEL2) determine which one of the eight data inputs (A0-A7, B0-B7) is propagated to the output.
BLOCK DIAGRAM
A0 A1 A2 A3 QA QA
PIN NAMES
Pin A0-A7 B0-B7 SEL0, 1, 2 QA, QB QA, QB VCCO Function A Data Inputs (D) B Data Inputs (D) Select Inputs True Outputs Inverting Outputs VCC to Output
A4 A5 A6 A7 SEL0 SEL1 SEL2
TO SIDE B
M9999-032006 hbwhelp@micrel.com or (408) 955-1690
Rev.: E
Amendment: /0
1
Issue Date: March 2006
Micrel, Inc.
SY10E163 SY100E163
PACKAGE/ORDERING INFORMATION
Ordering Information(1)
B6 B7 VCCO
Part Number SY10E163JC
18 17
Package Type J28-1 J28-1 J28-1 J28-1 J28-1 J28-1 J28-1 J28-1
Operating Range Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial
Package Marking SY10E163JC SY10E163JC SY100E163JC SY100E163JC SY10E163JZ with Pb-Free bar-line indicator SY10E163JZ with Pb-Free bar-line indicator SY100E163JZ with Pb-Free bar-line indicator SY100E163JZ with Pb-Free bar-line indicator
Lead Finish Sn-Pb Sn-Pb Sn-Pb Sn-Pb Matte-Sn Matte-Sn Matte-Sn Matte-Sn
B2 B3
25 24 23 22 21 20 19
B1 B0 SEL0 VEE SEL1 SEL2 A0
B4 B5
26 27 28 1 2 3 4 5 6 7 8 9 10 11
QB QB VCC NC VCCO QA QA
SY10E163JCTR(2) SY100E163JC SY100E163JCTR(2) SY10E163JZ(3) SY10E163JZTR(2, 3) SY100E163JZ(3) SY100E163JZTR(2, 3)
Notes:
PLCC TOP VIEW J28-1
16 15 14 13 12
A1 A2
A3 A4
28-Pin PLCC (J28-1)
A6 A7
A5
1. Contact factory for die availability. Dice are guaranteed at TA = 25C, DC Electricals only. 2. Tape and Reel. 3. Pb-Free package is recommended for new designs.
M9999-032006 hbwhelp@micrel.com or (408) 955-1690
2
Micrel, Inc.
SY10E163 SY100E163
TRUTH TABLE
SEL2 L L L L H H H H SEL1 L L H H L L H H SEL0 L H L H L H L H A/B Data 0 1 2 3 4 5 6 7
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0C Symbol IIH IEE Parameter Input HIGH Current Power Supply Current 10E 100E -- -- 73 73 88 88 -- -- 73 73 88 88 -- -- 73 83 88 100 Min. Typ. Max. -- -- 150 TA = +25C Min. Typ. -- -- Max. 150 TA = +85C Min. Typ. -- -- Max. 150 Unit A mA Condition -- --
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0C Symbol tPD Parameter Propagation Delay to Output D SEL0 SEL1 SEL2 Within-Device Skew An, Bn to Q An, Am to QA Bn, Bm to QB Rise/Fall Time 20% to 80% TA = +25C TA = +85C Max. 800 950 850 725 ps -- -- -- 275 40 30 30 375 -- -- -- 575 -- -- -- 275 40 30 30 375 -- -- -- 575 -- -- -- 275 40 30 30 375 -- -- -- 575 ps -- 1 Unit ps 400 525 425 350 550 725 625 525 800 950 850 725 400 525 425 350 550 725 625 525 800 950 850 725 400 525 425 350 550 725 625 525 Condition --
Min. Typ. Max. Min. Typ.
Max. Min. Typ.
tskew
tr tf
Note: 1. Within-device skew is defined as identical transition on similar paths through a device; n = 0-7, m n, m = 0-7.
M9999-032006 hbwhelp@micrel.com or (408) 955-1690
3
Micrel, Inc.
SY10E163 SY100E163
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
USA
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer. Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser's use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser's own risk and Purchaser agrees to fully indemnify Micrel for any damages resulting from such use or sale. (c) 2006 Micrel, Incorporated. M9999-032006 hbwhelp@micrel.com or (408) 955-1690
4


▲Up To Search▲   

 
Price & Availability of SY100E163

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X