|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Micrel, Inc. 2-BIT 8:1 MULTIPLEXER SY10E163 SY100E163 SY10E163 SY100E163 FEATURES s 850ps max. propagation delay s Extended 100E VEE range of -4.2V to -5.5V s Differential outputs s Internal 75K input pulldown resistors s Fully compatible with industry standard 10KH, 100K ECL levels s Fully compatible with Motorola MC10E/100E163 s Available in 28-pin PLCC package DESCRIPTION The SY10/100E163 offer two 8:1 multiplexers designed for use in new, high-performance ECL systems. The E163 has differential outputs and common select inputs. The select inputs (SEL0, SEL1, SEL2) determine which one of the eight data inputs (A0-A7, B0-B7) is propagated to the output. BLOCK DIAGRAM A0 A1 A2 A3 QA QA PIN NAMES Pin A0-A7 B0-B7 SEL0, 1, 2 QA, QB QA, QB VCCO Function A Data Inputs (D) B Data Inputs (D) Select Inputs True Outputs Inverting Outputs VCC to Output A4 A5 A6 A7 SEL0 SEL1 SEL2 TO SIDE B M9999-032006 hbwhelp@micrel.com or (408) 955-1690 Rev.: E Amendment: /0 1 Issue Date: March 2006 Micrel, Inc. SY10E163 SY100E163 PACKAGE/ORDERING INFORMATION Ordering Information(1) B6 B7 VCCO Part Number SY10E163JC 18 17 Package Type J28-1 J28-1 J28-1 J28-1 J28-1 J28-1 J28-1 J28-1 Operating Range Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Package Marking SY10E163JC SY10E163JC SY100E163JC SY100E163JC SY10E163JZ with Pb-Free bar-line indicator SY10E163JZ with Pb-Free bar-line indicator SY100E163JZ with Pb-Free bar-line indicator SY100E163JZ with Pb-Free bar-line indicator Lead Finish Sn-Pb Sn-Pb Sn-Pb Sn-Pb Matte-Sn Matte-Sn Matte-Sn Matte-Sn B2 B3 25 24 23 22 21 20 19 B1 B0 SEL0 VEE SEL1 SEL2 A0 B4 B5 26 27 28 1 2 3 4 5 6 7 8 9 10 11 QB QB VCC NC VCCO QA QA SY10E163JCTR(2) SY100E163JC SY100E163JCTR(2) SY10E163JZ(3) SY10E163JZTR(2, 3) SY100E163JZ(3) SY100E163JZTR(2, 3) Notes: PLCC TOP VIEW J28-1 16 15 14 13 12 A1 A2 A3 A4 28-Pin PLCC (J28-1) A6 A7 A5 1. Contact factory for die availability. Dice are guaranteed at TA = 25C, DC Electricals only. 2. Tape and Reel. 3. Pb-Free package is recommended for new designs. M9999-032006 hbwhelp@micrel.com or (408) 955-1690 2 Micrel, Inc. SY10E163 SY100E163 TRUTH TABLE SEL2 L L L L H H H H SEL1 L L H H L L H H SEL0 L H L H L H L H A/B Data 0 1 2 3 4 5 6 7 DC ELECTRICAL CHARACTERISTICS VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND TA = 0C Symbol IIH IEE Parameter Input HIGH Current Power Supply Current 10E 100E -- -- 73 73 88 88 -- -- 73 73 88 88 -- -- 73 83 88 100 Min. Typ. Max. -- -- 150 TA = +25C Min. Typ. -- -- Max. 150 TA = +85C Min. Typ. -- -- Max. 150 Unit A mA Condition -- -- AC ELECTRICAL CHARACTERISTICS VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND TA = 0C Symbol tPD Parameter Propagation Delay to Output D SEL0 SEL1 SEL2 Within-Device Skew An, Bn to Q An, Am to QA Bn, Bm to QB Rise/Fall Time 20% to 80% TA = +25C TA = +85C Max. 800 950 850 725 ps -- -- -- 275 40 30 30 375 -- -- -- 575 -- -- -- 275 40 30 30 375 -- -- -- 575 -- -- -- 275 40 30 30 375 -- -- -- 575 ps -- 1 Unit ps 400 525 425 350 550 725 625 525 800 950 850 725 400 525 425 350 550 725 625 525 800 950 850 725 400 525 425 350 550 725 625 525 Condition -- Min. Typ. Max. Min. Typ. Max. Min. Typ. tskew tr tf Note: 1. Within-device skew is defined as identical transition on similar paths through a device; n = 0-7, m n, m = 0-7. M9999-032006 hbwhelp@micrel.com or (408) 955-1690 3 Micrel, Inc. SY10E163 SY100E163 28-PIN PLCC (J28-1) Rev. 03 MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 TEL USA + 1 (408) 944-0800 FAX + 1 (408) 474-1000 WEB http://www.micrel.com The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer. Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser's use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser's own risk and Purchaser agrees to fully indemnify Micrel for any damages resulting from such use or sale. (c) 2006 Micrel, Incorporated. M9999-032006 hbwhelp@micrel.com or (408) 955-1690 4 |
Price & Availability of SY100E163 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |